Sineng Electric launches 510 kW high-power string inverter for utility-scale solar

Sineng Electric’s SP-510K-H is a 510 kW high-power string inverter for utility-scale solar projects, featuring 1,650 V DC input, 1,000 V AC output, six MPPTs, and support for DC/AC ratios up to 1.8. The inverter delivers up to 99.0% efficiency, grid-forming capability for weak grids, AI-based O&M functions, and operation at altitudes up to 4,000 m.
Image: Sineng Electric

Chinese manufacturer Sineng Electric has introduced the SP-510K-H, a high-power string inverter for utility-scale solar projects.

Built for project block configurations exceeding 7 MW, the inverter measures 1,210 mm x 900 mm x 413 mm and weighs 135 kg. It supports a maximum DC input voltage of 1650 V, enabling longer string layouts—adding two to three additional modules per string—to significantly reduce mounting structure and balance-of-system (BOS) costs.

On the AC side, the inverter has a 1,000 V output rating to reduce line losses and supports aluminum cabling and power line communication (PLC) to further lower BOS costs.

The transformerless inverter offers a maximum efficiency of 99.0% and a European efficiency of 98.8%. It features six maximum power point trackers (MPPTs) supporting up to 36 strings and allows a DC/AC ratio of up to 1.8.

Sineng Electric said the SP-510K-H incorporates grid-forming capabilities for operation in weak grids with a short-circuit ratio (SCR) of 0.93 or higher. The company said the inverter supports black-start capability and wide-band oscillation suppression to improve grid restoration and stability. It also provides dynamic frequency regulation with virtual inertia adjustment from 0 seconds to 20 seconds and a reactive power response time of 10 ms.

For operations and maintenance, the inverter includes AI-based power generation forecasting, automated current-voltage (I-V) and capacitance-voltage (C-V) curve diagnostics, and MPPT-level insulation monitoring for fault detection and localization.

Safety features include AFCI 2.0 arc-fault detection, terminal temperature monitoring, millisecond-level fault isolation, and Type I+II DC surge protection.

The inverter has an IP66-rated enclosure, IP68-rated cooling fans, C5 corrosion protection, and is designed to operate at full power at altitudes of up to 4,000 m.

“MPPT-level insulation monitoring enables precise fault localization, significantly improving troubleshooting efficiency and reducing downtime. Real-time AC and DC terminal temperature monitoring provides early warning of overheating,” the manufacturer said in a statement.

This content is protected by copyright and may not be reused. If you want to cooperate with us and would like to reuse some of our content, please contact: [email protected].