pv magazine test: October 2025 results

Share

Irradiance and temperature conditions at the Yinchuan test installation site continued on a downward trend in October 2025. But this did not influence the performance or the ranking of the products. The Risen heterojunction product was removed from the installation for examination.

Specific energy yield ranking – Yinchuan, October 2025

# Installation Month Product Type Total 2025 September kWh/m2 Total 2025 September Wh/Wp September 2025 Rank (Wh/Wp) Total 2025 October kWh/m2 Total 2025 October Wh/Wp October 2025 Rank (Wh/Wp)
60 2024/12/8 Runergy HY-DH144N8-570 Bifacial n-TOPCon 26.80 122.66 1 25.85 118.34 1
66 2025/6/5 AE AE605CMER-132-BDS Bifacial n-TOPCon 23.83 122.55 1 22.94 117.99 1
61 2024/12/9 JA JAM72D42-615/LB Bifacial n-TOPCon 27.52 122.57 1 26.42 117.68 1
62 2025/3/5 SEG Solar SEG-BTC-600-BG Bifacial n-TOPCon 26.84 121.45 1 25.93 117.34 1
50 2024/12/8 Astronergy CHSM72N(DG)/F-BH-580 Bifacial n-TOPCon 26.78 121.01 1 25.81 116.60 1
63 2025/3/5 Astronergy CHSM66RN(DG)/F-BH-615 Bifacial n-TOPCon 27.38 120.65 2 26.40 116.32 2
57 2024/12/8 AE AE570CMD-144BDS Bifacial n-TOPCon 26.63 120.44 2 25.63 115.93 2
54 2024/12/8 Trina TSM-685NEG21C.20 Bifacial n-TOPCon 26.76 120.17 2 25.79 115.81 2
56 2024/12/8 Longi LR5-72HGD-585M Bifacial n-TOPCon 27.00 120.16 2 25.99 115.68 2
58 2024/12/8 SolarSpace SS9-66HD-695N Bifacial n-TOPCon 27.07 120.24 2 26.04 115.63 2
59 2024/12/8 DMEGC DM605G12RT-B66HSW Bifacial n-TOPCon 26.56 120.02 2 25.56 115.53 2
53 2025/1/1 SEG SEG-575-BTA-BG Bifacial n-TOPCon 26.89 118.75 3 25.89 114.32 3

Specific energy yield ranking – Dammam, October 2025

# Installation Month Product Type Total 2025 September kWh/m2 Total 2025 September Wh/Wp September 2025 Rank (Wh/Wp) Total 2025 October kWh/m2 Total 2025 October Wh/Wp October 2025 Rank (Wh/Wp)
62 2025/5/8 SEG Solar SEG-BTC-600-BG Bifacial n-TOPCon 36.09 180.26 1 38.19 190.74 1
63 2025/5/8 Astronergy CHSM66RN(DG)/F-BH-615 Bifacial n-TOPCon 35.44 173.91 2 37.53 184.16 2

On Oct. 15, there was a power cut in Dammam, and the meteo and production data from this day have been removed from the results. At the test site in Dammam, high temperatures and strong irradiance conditions continued throughout the month, and there was little change in the performance of the modules installed there.

George Touloupas and Huatian Xu