Scientists in Germany have collected dust from Qatar, Morocco and Thailand to analyze the impact on the performance of uncoated solar glass and uncoated PV mini-modules. Their analysis has shown that dust coverage could range from 4% to 60%.
Researchers in South Korea have found that the contamination by small amounts of soldering flux residues during heterojunction PV module manufacturing can induce significant long-term performance degradation. Careful control of flux application methods and incorporating drying steps are proposed as potential solutions.
Italy-based Heiwit has developed a 200 Ah sodium-ion battery with a lifespan of 6,000 cycles. The device reportedly offers thermal stability and rapid charging speed.
The US-based heating specialist said its new variable-speed water–to–water system has a coefficient of performance of 3.2 at full load and 3.8 at part load.
Researchers from Swiss and Austrian institutions have demonstrated a novel design for a glass-free, structurally robust silicon PV module. With a weight below 6 kg/m2, the targeted application is older buildings with weak roof structure.
Researchers in the Netherlands have identified all major solar power plants in the Dutch Province of Gelderland and have analyzed all of their spatial measures in an effort to assess their impact on landscape. They have specifically focused on land use competition, biodiversity, and landscape experience.
Researchers in the Middle East claim to have identified the optimal parameters for the commercial production of perovskite-silicon tandem solar modules across several locations. Their analysis showed that manufacturing costs may currently be as low as $0.387/W, with the prospect of reaching $0.25/W in seven years.
Chinese energy storage speciliast Hithium has completed a landmark UL-supervised fire safety trial, signaling a step-change in system-level fire protection for grid-scale battery storage.
A review of using statistical probability to understand solar production outcomes.
Researchers in Brazil have installed a vertical thermistor chain with six temperature loggers beneath a floating PV plant and at a nearby reference site. The system also recorded dissolved oxygen and photosynthetically active radiation to assess environmental impacts.
This website uses cookies to anonymously count visitor numbers. View our privacy policy.
The cookie settings on this website are set to "allow cookies" to give you the best browsing experience possible. If you continue to use this website without changing your cookie settings or you click "Accept" below then you are consenting to this.